25 Record – Stadia Observation
The GeoSurvey program can reduce stadia observations in this format:
EDM format (booking method=4)
Data |
Content |
Columns |
length |
Record Type | 25 | 1-2 | 2 |
Slope Distance | ____ | 3-10 | 8 |
Height of Target | ____ | 11-18 | 8 |
unused | ____ | 19-26 | 8 |
Vertical Angle | ____ | 27-33 | 7 |
Horiz Bearing | ____ | 34-40 | 7 |
Code | ____ | 41-50 | 10 |
Observed Station | ____ | 51-54 | 4 |
Remark | ____ | 55-74 | 20 |
Point Number | ____ | 75-79 | 5 |
TOTAL Station format (booking method=5)
Data |
Content |
Columns |
length |
Record Type | 25 | 1-2 | 2 |
Horiz Distance | ____ | 3-10 | 8 |
Height of Target | ____ | 11-18 | 8 |
Vert Displacement | ____ | 19-26 | 8 |
unused | ____ | 27-33 | 7 |
Horiz Bearing | ____ | 34-40 | 7 |
Code | ____ | 41-50 | 10 |
Observed Station | ____ | 51-54 | 4 |
Remark | ____ | 55-74 | 20 |
Point Number | ____ | 75-79 | 5 |